STANDARD METHOD FOR MEASURING FLOOR AREA IN OFFICE BUILDINGS Q and A
1. Q: Please explain the alternate method for calculating Rentable
Area for each tenant. I am averaging the individual floor R/U ratios
but the result doesn’t equal the Building R/U Ratio.
A: The R/U ratio will usually differ for each floor, so that a building
typically will not have just one R/U ratio. Since Floor Common Areas
vary according to corridor configuration on the various floors, likewise
the floor R/U ratio varies for each floor. The R/U ratio to be used
on a floor is the product of the Floor R/U and the Building R/U (Floor
R/U x Building R/U = R/U for that floor). Each floor of a building will
have an R/U ratio by using this method.
2. Q: If a private stairway is built between two floors occupied by
one tenant, is that stairway part of Rentable Area? Is it part of the
Usable Area?
A: Yes. The Standard states specifically that vertical penetrations
built for the private use of a tenant occupying Office Areas on more
than one floor are counted as Rentable. The stairway would also be part
of the Usable Area of the tenant.
3. Q: Are areas outside the fire resistance enclosure of a Major Vertical
Penetration considered part of that penetration? For example, plumbing
chases behind restrooms?
A: Walls enclosing the major vertical penetration, which are required
by building codes, are part of the penetration. Additional walls outside
these enclosing walls are not considered part of the penetration and
are not deducted from Rentable Area.
4. Q: How are “enclosing walls” defined in conjunction with Major Vertical
Penetrations? What about the floor of the stair tower or the elevator
pits of the elevator shaft?
A: The term “enclosing walls” refers to those walls required by building
code, and not to the architectural or decorative treatments of those
walls. The floor of a stair tower and the pits of the elevator shaft,
when found inside the enclosing walls, are part of the Major Vertical
Penetration. However, if an area is not within the enclosing walls (such
as a storage room under the stair tower), the area is part of the Rentable
Area.
5. Q: Regarding “Dominant Portion”... where a wall meets a column (such
as in the illustration on page 7), a “bite” appears to be taken out
of the column as the measurement line shifts. If the column is not square,
how are the dimensions of the “bite” determined?
A: Columns are not considered in the Standard. Therefore, where a column
interrupts the Dominant Portion, the Dominant Portion that exists on
each side of the column continues through one-half of the horizontal
distance of the column. Where a column interrupts a Dominant Portion
that is the same on both sides, the Dominant Portion continues through
the column as if the column did not exist. Where a column interrupts
a Dominant Portion that is different on each side, the Dominant Portion
on one side continues for one-half the horizontal distance and then
either steps in or out to meet the Dominant Portion from the other side.
6. Q: Are Major Vertical Penetrations included in Store Area?
A: No, major vertical penetrations are excluded when calculating Store
Area. Rentable Area itself excludes Major Vertical Penetrations — and,
since store area is less than or equal to Floor Rentable Area on the
floor where the store is located, Store Area likewise will exclude Major
Vertical Penetrations.
7. Q: Are “areas of refuge” (mainly a feature of Canadian buildings)
deducted as Major Vertical Penetrations?
A: If the area of refuge is not isolated from the stairwell, then it
is part of the Major Vertical Penetration and deducted as such. If the
area of refuge is isolated from the stairwell with its own set of doors,
then it is part of Floor Rentable Area and distributed to each Office
Area through the application of the R/U Ratio.
8. Q: If a Store Area is on a corner, is the measurement taken to the
building line on both sides? Does it matter whether entrances to the
space are located on both sides?
A: Store Area requires a street frontage and a ground level. It is possible
for a square building to meet these conditions on every one of its sides.
In that situation and on that level, the Dominant Portion would be the
building line on each side. However, the sides do not have to be at
the same level. A building can have street frontage and ground level
on one side (e.g., Floor 1) and street frontage and ground level (e.g.,
Floor 3). Each of those two floors would be considered Store Area, and
the Dominant Portion would be the building line. Having a separate street
entrance for the space is not a requirement in determining street frontage
for a Store Area.
9. Q: How is building line defined where the ground floor building
face is set back further than the upper floors from the street frontage?
A: The Standard is intended to measure space that is fully enclosed.
Therefore the building line, as used in the Standard to determine Store
Area, is the outside face of the column line (or the exterior building
surface if columns are not present) of the ground floor on the street
frontage exposure. Deviations to the building line, including projections
or recesses, are ignored unless they are part of the permanent building
exterior of the ground floor.
10.Q: Is a courtyard included in Building Common Area if it is enclosed
by four sides but not a roof? (See reference to “fully enclosed courtyard
outside the exterior walls” at top of page 3 of the Standard and illustration
on page 19.)
A: “Fully enclosed” refers to an enclosed space where environmental
conditions are maintained by a heating, ventilating and air conditioning
system. So there must be a roof in order for the courtyard to be fully
enclosed.
11.Q: On an above-ground floor, can a corridor that is ordinarily Floor
Common Area be assessed to a particular tenant if it provides the only
access to their space? Similarly, can a portion of a ground floor lobby
that is ordinarily part of Building Common Area be assessed to a particular
tenant if it provides the only access to their space?
A: Corridors by their nature typically provide the only access to an
office or store, even when the corridor is required primarily for fire
egress. The Standard allows, on page 16, that “Where alcoves, recessed
entrances or similar deviation from the corridor line are present...”
they may be part of the Usable Area, just like the space would have
been if the deviation had not occurred. You should first determine whether
the suite entrance could be positioned to incorporate the area in question
without obstructing other occupants, fire egress, or other building
services, before deciding that the area belongs to the Usable Area of
an office or store. Remember that no area can be accounted for more
than once. If an area belongs to the Usable Area of an office or store,
it must be excluded from Floor Common Area, Building Common Area, or
the Usable Area of any other office or store.
12.Q: Can a mechanical room serving tenants on an above-ground floor
be part of Building Common Area?
A: Yes, if it is not already part of a Floor Common Area.
13.Q: Does the Standard measure space on belowground floors?
A. Yes, except for those areas specifically excluded by the Standard,
such as parking areas. STANDARD METHOD FOR MEASURING FLOOR AREA IN OFFICE
BUILDINGS • ANSWERS TO 26 KEY
14.Q: Is storage space part of Building Common Area in a multi-tenant
building? Is storage space Usable if it is for the express use of a
given tenant?
A: Areas that are used for storage, whether above or below grade, are
measured just like an Office (or Store in the cases of street frontage),
because these spaces could house tenants’ personnel, furniture, files
or supplies. If the space is a common storage area available for use
by all tenants at no additional charge, than it would be calculated
under Building Common Area. If it is for the express use of a given
tenant, the storage space would have both a Usable and Rentable measurement.
15.Q: Is parking ever counted as Rentable?
A: No, the Standard excludes parking space.
16.Q: If a tenant expands its Rentable Area, does the Floor R/U Ratio
and Building R/U Ratio change as a result — meaning that each tenant’s
Rentable Area would change?
A: Tenant expansion and new tenant activity may indeed affect the Floor
R/U Ratio and/or Building R/U Ratio. If tenant expansion or new tenant
activity occurs in part or all of an existing Store Area or Office Area,
the ratios remain unchanged. However, if tenant expansion or new tenant
activity incorporates what had been Floor Common Area or Building Common
Area into the newly created Store or Office Area — or creates additional
Floor Common Area or Building Common Area from what was previously Store
or Office Area — then one or both ratios will be affected. The Floor
R/U Ratio will change if Floor Common Area is increased or decreased
(e.g., by changing the configuration of floor circulation corridors
or enlarging a restroom). The Building R/U Ratio will change if Building
Common Area is increased or decreased (e.g., by leasing an exercise
room) or if the Floor R/U Ratio is adjusted on a floor containing Building
Common Area. Changes to the Floor R/U Ratio and Building R/U Ratio will
affect the Rentable Area of all the offices or stores located on that
floor or in the building. For purposes of stability, adjustments to
existing leases based on changes to Rentable Area are typically not
made, although the new ratios are used in future lease transactions.
17.Q: Regarding the illustration on page 16 of the Standard... Is the
measurement taken to the center line of partitions between adjoining
tenant spaces and to the center line of partitions between tenant spaces
and Building Common Areas?
A: Yes. The measurement is taken to the center line of partitions between
adjoining Office Area(s) or Store Area(s), Building Common Area(s) and
the Building Common Area being measured. Building Common Area is measured
just like Office or Store Area in determining Usable Area.
18.Q: It is stated in the Standard (on page 14) that “Building Common
Areas are considered to be part of Floor Usable Area.” Can this possibly
mean that the Building Common Areas on a ground-level floor (see the
illustration on page 22) are to be measured twice?
A: No — the Standard does not allow the same space to be measured twice.
The illustration on page 14 shows all the area that is part of the Floor
Usable Area, which includes both Store Area and Building Common Area.
Similar to the illustration on page 20 that deals specifically with
Store Area and how it is measured, the illustration on page 22 highlights
Building Common Area. Illustrations on page 20 and 22 are components
of the Floor Usable Area for the ground-level floor. Together they are
the Floor Usable Area illustrated on page 14. The intent of the Standard
is for Building Common Area to be part of the Floor Usable Area. Building
Common Area needs to take part of the Floor Common Area allocation on
the floor(s) on which the Building Common Area is located. Building
Common Area, just like Store Area and Office Area, benefits from the
circulation corridors and other Floor Common Areas. This allocation
is necessary in order to fairly distribute the Floor Common Area to
the users. If the allocation was not made, occupants on floors with
Building Common Area would receive an unfair higher allocation of Floor
Common Area. STANDARD METHOD FOR MEASURING FLOOR AREA IN OFFICE BUILDINGS
• ANSWERS TO 26 KEY 19.Q: Why isn’t the exercise club (area #14) and
restaurant (area #19) part of Building Common Area as illustrated on
page 22 if they are serving the entire building? A: These areas represent
rent-paying tenants — so while they do provide a service to the entire
building (indeed to any paying customer), they are Store Area rather
than Building Common Area. However, if these areas were a building amenity
that all tenants could use as part of their lease, then they would be
considered Building Common Area instead.
20.Q: In an office complex, would mechanical areas located in one building
— but which serve others as well — be considered Building Common Area?
What about underground corridors that link one building with another?
A: Although the Standard does not deal specifically with building complexes,
it would be a reasonable adaptation to consider the entire project as
one building and to allocate the common corridors and building mechanical
area as allowed through Building Common Area.
21.Q: Is atrium space measured by the Standard?
A: Atrium space above the main lobby floor does not constitute Rentable
Area. It is empty space and is treated, in effect, as a Major Vertical
Penetration. The base of the atrium, however (i.e., the finished floor)
is measured.
22.Q: Are mezzanines measured by the Standard?
A: All floor space in a building is measured, including mezzanines.
The purpose of the Standard is to measure the actual square feet contained
in the building. The usefulness of a particular space is not addressed
by the Standard, and is better left for lease negotiations between Landlord
and Tenant. Varying lease rates are common in the market using such
criteria as location on the floor, proximity to the elevator lobby,
windows, views, height in the building, and the usefulness of a particular
space.
23.Q: On a single tenant floor, are the elevator lobby and restrooms
considered Usable Area?
A: The BOMA Standard defines Usable Area as space that tenants can actually
occupy and use and may allocate to house personnel and furniture. Thus,
if an elevator lobby is under the tenant’s control and could be put
to use (as a reception area, for instance), it is Usable Area. However,
if the tenant cannot use that space because of fire code or other restrictions,
it is not Usable Area. Restrooms are not considered Usable Area under
the Standard, although they are part of Rentable Area.
24.Q: Is Gross Building Area an appropriate way to measure a single
occupant building?
A: The Standard is a systematic method for measuring office buildings,
and should be used in its entirety for each building. Its purpose is
to provide a common and agreed-upon basis for comparing lease rates,
building efficiencies, operating costs and other relevant data. For
example, Gross Building Area is used within the industry primarily to
determine construction costs or building value. Usable Area is often
used to determine cleaning costs and space efficiencies. Single occupant
buildings will often need to be compared to multi-occupant buildings
and, in these cases, Building Rentable Area is the recommended measurement
to use. Gross Building Area would be an appropriate method in determining
lease rate only if the parties agree. Each part of the Standard has
its own use and needs to be applied regardless of the number of occupants.
25.Q: Does the Standard provide for the measurement of warehouse or
industrial space? Does it cover a shopping center or strip mall?
A: The Standard is intended to apply specifically to the measurement
of office buildings, whether multitenant, single tenant, or owner-occupied.
A method for measuring Store Area in office buildings is contained in
the Standard. No provision is currently made for measuring any other
types of buildings.
|